This article mainly introduces:

Estonia hydraulic cylinder,tailboard balance cylinder manufacturer,tailboard balance cylinder

Estonia tailboard balance cylinder

(Estonia tailboard balance cylinder,produced by Hengyu Hydraulic Co., Ltd)

tailboard balance cylinder are widely used in Estonia,because of excellent fatigue and impact resistance,no need for deceleration device,long service life.So our company has designed tailboard balance cylinder for customers from Estonia.

Introduction to tailboard balance cylinder:

The piston seal of the tailboard balance cylinder is the main element to prevent leakage in the tailboard balance cylinder. For the lip seal, it should focus on checking whether the lip edge is bruised and worn, and for the combination seal, it should focus on checking the wear of the sealing surface, and then determine whether the seal can be used. In addition, it is necessary to check whether the static seal between the piston and the piston rod is crushed. The piston rod seal should focus on checking the wear of the seals and supporting rings.

tailboard balance cylinder to reasonable use of hydraulic oil: strict hydraulic oil selection off. Hydraulic oil is selected in strict accordance with oil standards. The selection of good quality hydraulic oil can effectively prevent bubbles in the working process of the hydraulic system. When choosing the oil, it should be selected according to the lowest temperature in different regions, and fill the hydraulic oil according to the dipstick standard, and at the same time, it should also keep the hydraulic system clean (when filling the hydraulic oil, it should prevent the water and other impurities into it), and often check the oil quality, oil level and oil color of the hydraulic oil. If blisters and bubbles are found in the hydraulic oil. When the oil becomes milky white, the source of the air in the oil should be carefully found and eliminated in time.

When the tailboard balance cylinder thrust is insufficient, check the hydraulic circuit for leaks. Including leakage of valves and hydraulic lines. The inspection method is to check and eliminate the leakage of the hydraulic connection line by manipulating the reversing valve. Also consider the relief valve. If the relief valve enters the dirt and jams the spool, so that the relief valve is normally open, the hydraulic oil will flow directly back to the tank through the relief valve bypass, resulting in no oil in the tailboard balance cylinder. If the load is too large, although the regulating pressure of the relief valve has reached the maximum rating, the tailboard balance cylinder still cannot get the thrust required for continuous action without action. If the regulating pressure is low, the pressure is insufficient to achieve the required vertebra force, which is manifested as insufficient thrust. Check and adjust the relief valve at this time.

The viscosity of the working oil used in the tailboard balance cylinder is 29~74mm2/S, and ISO VG46 anti-wear hydraulic oil is recommended. Working oil temperature within the range of -20~80. C. When the ambient temperature and service temperature are low, the oil with lower viscosity can be selected.

Answers to some questions about tailboard balance cylinder:

Is there a way to make the cylinder stop pushing when it hits something hard during the process of pushing?
The simplest solution is to press the stop switch, this switch has a mechanical type, touch the object on the action or send a stop signal, through the operation of the motor control cylinder; There is also an induction switch, that is, when the hydraulic cylinder expands to the range of the induction switch can sense the signal, it sends a signal to let the motor act, resulting in the corresponding action of the cylinder.

Why hydraulic cylinder load can not rise?
The hydraulic cylinder does not top up indicates that the pressure of the working chamber of the hydraulic cylinder is insufficient, and the following circumstances can lead to insufficient pressure: 1) The relief valve of the hydraulic system cannot establish pressure, elimination method: check whether the pressure setting screw of the relief valve is screwed to the appropriate position. If it is an electromagnetic relief valve, please check the power-on condition. 2) The hydraulic system pipeline is connected incorrectly, when P and T are connected, this must be checked and excluded; 3) Excessive leakage in the hydraulic cylinder, resulting in (only for double-acting cylinders); 3) No hydraulic oil into the working chamber of the hydraulic cylinder, elimination method: first disassemble the hydraulic pipe connecting the reversing valve and the hydraulic cylinder, and then control the reversing valve, and observe whether there is hydraulic oil flowing out of the reversing valve.